Article source:
Applications
These heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobile equipment requiring grounding conductors, where a ground check conductor, and metallic shielding are required.
Standards
Construction
Options:
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
Dimensions and Weight:
Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | ||||
No. of cores×AWG/kcmil | - | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
3×2/0 | 342 | 5 | 16 | 0.08 | 2.0 | 0.205 | 5.2 | 2.09 | 53.1 | 3400 | 5059 | 243 |
3×3/0 | 418 | 4 | 16 | 0.08 | 2.0 | 0.205 | 5.2 | 2.21 | 56.1 | 3934 | 5853 | 279 |
3×4/0 | 532 | 3 | 16 | 0.08 | 2.0 | 0.220 | 5.6 | 2.36 | 59.9 | 4860 | 7231 | 321 |
3×350 | 888 | 1 | 16 | 0.95 | 2.4 | 0.250 | 6.3 | 2.81 | 71.4 | 7400 | 11010 | 435 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.